Our new UF-series of urinalysis devices is unique. Using fluorescence flow cytometry, the UF-1000i offers two separate channels: one for bacteria and one for sediment particles. This means you can now detect possible urinary tract infections in about one minute instead of hours, and at a. XS-1000i-Operators-Instructions-pdf (1).pdf - Free ebook download as PDF File (.pdf), Text File (.txt) or read book online for free. Scribd is the world's largest social reading and publishing site. Search Search. Save Save XS-1000i Operators Instructions.pdf. Specified in the manual or the user's. The screen and manual setting targets. Sysmex XS-1000i/XS-800i. The XS-1000i provides rapid, reliable test results from just 20uL of sample for assistance in patient diagnosis and therapeutic monitoring. It utilizes the same state-of-the-art diagnostic power and accuracy as the X-Series (XE-Series, XT-Series) of high volume analyzers with comparable results. Oct 18, 2018 Home › Forums › 'Zebra' Adidas Yeezy Boost 350 V2 Restock Will Reportedly Be More Available This Time › -ONLINE- Sysmex xs-1000i user manual pdf.923. Tagged: manual, pdf, Sysmex, user, xs-1000i 1 voice, 0 replies Viewing 1 post (of 1 total) Author Posts December 17, 2018 at 7:05 am #5459 AnonymousInactive @ Download Download. XP-300 Quick Guide-Document Number 1051-CFL, Revision 2 June/2014 Page 3 Quality Control Analysis Running QC 1. Verify the XP-300 is at Ready. Press the QC button. Press the Quality Control file to be analyzed. Mix the control blood according to the package insert. Remove the cap and set control blood container to the sample probe.
One moment please..
- Parts
- Videos
- News
DESCRIPTION
Small sample size is a perfect fit for labs with pediatric or oncology patients.Sysmex was the first company to use fluorescent flow cytometry and cell counting methods to reliably detect abnormal samples and reduce false positives. Take advantage of our experience.
FORUMSView All (6)
Ask a New Question2Replies5 months ago | 5 months agoadmin password admin passwordReply |
-Keta Patel 7 years ago | 7 years agonot able to receive data from com1 port i am developing healthcare application . i am facing problem during receiving data from com1 port throwing by IPU Host. i got connect with com1 port and able to open the port but i am not receiving whole data in stead of i get only 1 cahracter and last terminator character . if any have code sample for that pls help me thanks Reply |
1Reply7 years ago | 7 years agooverheating Sysmex XT1800i The machine stops working after a few samples. The error message is FCM sheath overheated. What should we do? the machine is only 2 months old. Mi WiFi Router Pro; User Manuals for Xiaomi Audio: 1More Crystal Piston In-Ear Headphones; 1More Voice of China Headphones; Beva Magic Star Bluetooth Speaker; Mi Bluetooth Headset; Mi Bluetooth Speaker; Mi Bunny MITU Bluetooth Speaker; Mi Headphones; Mi In-Ear Headphones Pro; Mi Internet Radio; Mi Internet Speaker; Mi Piston V2 In-Ear Headphones. Mi bluetooth sports headset user manual. Mi Sports Bluetooth Earphones User Manual. Getting started Medium ear tips suit most people, try them before you decide to switch to a different size. Large Medium Small Multifunction button. Find 'Mi Sports Bluetooth Earphones' among the devices on your phone and connect. Reply |
DOCUMENTS / MANUALSView All
FEATURES
Standardized
- Fully automated sample preparation(mixing, aspirating, diluting, staining)* Objective particle characterizationand identification based on detectionof forward scatter, fluorescence andimpedance signals and on adaptivecluster analysis* Automatic sample validationsupported by extensive user-definableflagging system* Automatic sample validation for reviewor output to host computer/printeraccording to user definable system settingEfficient workflow* Easy handling with keypadand status messages* Fast sample processing* Batch analysis with sampler orimmediate analysis of stat
Additional Specifications
Parameters:
WBC,RBC,HGB,HCT,MCV,MCH,MCHC,PLT,
Neut%, Lymph%, Mono%, Eo%, Baso%,
Neut#, Lymph#, Mono#, Eo#, Baso#,
RDW-SD, RDW-CV, MPV
80 samples/hour
Aspiration Volume:
sampler or manual closed mode: 150µL
manual open mode: 85µL
capillary mode: 40µL
Data Storage:
10,000 samples (incl. graphics)
5,000 patients’ information
1,000 selective test orders
Comprehensive QC files including
“Current” and “New” lot feature
1 XbarM file with 300 data points
Online QC
Host, line printer, graphic printer
Main unit: 20.5x24.8x19.7/114.6
Sampler: 20.5x 8.7x 4.3/15.4
Pneumatic unit: 11.2x 14x 15.8/35.3
Rack sampler for 50 sample tubes
Hand-held barcode scanner
WBC,RBC,HGB,HCT,MCV,MCH,MCHC,PLT,
Neut%, Lymph%, Mono%, Eo%, Baso%,
Neut#, Lymph#, Mono#, Eo#, Baso#,
RDW-SD, RDW-CV, MPV
80 samples/hour
Aspiration Volume:
sampler or manual closed mode: 150µL
manual open mode: 85µL
capillary mode: 40µL
Data Storage:
10,000 samples (incl. graphics)
5,000 patients’ information
1,000 selective test orders
Comprehensive QC files including
“Current” and “New” lot feature
1 XbarM file with 300 data points
Online QC
Host, line printer, graphic printer
Main unit: 20.5x24.8x19.7/114.6
Sampler: 20.5x 8.7x 4.3/15.4
Pneumatic unit: 11.2x 14x 15.8/35.3
Rack sampler for 50 sample tubes
Hand-held barcode scanner
One moment please..
Instruction Manual
- Parts
- Videos
- News
DESCRIPTION
The Sysmex XT-4000i offers medium to high volume laboratories an automated hematology system that can truly meet and exceed expectations.Designed to be reliable and efficient, the Sysmex XT-4000i offers medium to high volume laboratories an automated hematology system that can truly meet and exceed expectations. The XT-4000i provides a 6-part WBC differential, including enumerated Immature Granulocytes (IG # and %) to minimize slide reviews. The analyzer has a second fluorescent platelet method, PLT-O, on-board to help resolve platelet flags and minimize manual counts. Reticulocytes are fully automatic and require no pretreatments or testing delays. Body fluid samples, including CSF, serous fluid and synovial fluid, are analyzed. The seven (7) parameters reported include a 2-part WBC differential. The XT-4000i streamlines your workflow by providing testing for up to 100 samples per hour on whole blood, enabling rapid turnaround time.
FORUMSView All (2)
Ask a New Question1Reply3 years ago | 3 years agoMaterial data sheet of the reagents Pls i need the material data sheet for all the reagents for XT 4000iReply |
-Dr. Esmarkh 3 years ago | 3 years agoPm kit Hi , All! List pm kit components is needed! Thanks a lot!Reply |
![Manual Manual](/uploads/1/2/5/1/125133116/528517252.jpg)
DOCUMENTS / MANUALSView All
FEATURES
Sysmex Xs 1000i Instruction Manual
Immature granulocyte count (IG%, #) with reportable, quantitative results for metamyelocytes, myelocytes and promyelocytes
- Reduce false positive and false negative rates * Improve turnaround time with fewer manual differentials Platelet counts by a fluorescent optical method and by traditional impedance technology to improve accuracy of very low and very high PLT counts * Obtain accurate counts when interferences are present * Offers automated judgment for reporting PLT-O or PLT-I through instrument settings Retic: Fluorescent reticulocyte count to reduce manual confirmation methods and the inherent errors * Eliminate common interferences to avoid manual counts RET-He: Reticulocyte hemoglobin content measures the incorporation of iron into the red cell to assist the physician with anemia evaluation and management (e.g., functional iron deficiency anemia) * Provides rapid and direct analysis of an earlier stage of RBC development * Supports effective monitoring of costly drug protocols for cell stimulation Body Fluids: Excellent low end sensitivity with seven parameters, including a 2-part differential to eliminate the need for manual counts * Includes a 2-Part differential * Automated background check prior to analyzing a sample
SPECIFICATIONS
Sysmex Xs 1000i User Manual Pdf File
Height | 24.8 in |
Length | 28.3 in |
Weight | 113 lbs |
Width | 20.9 in |
Additional Specifications
Sysmex 1000i Instruction Manual
Principles & Technologies
Fluorescent Flow Cytometry: WBC-Diff, IG, RET, IRF, PLT-O
Hydrodynamic Focusing, Direct Current: RBC, HCT, PLT
Non-cyanide, Sodium Lauryl Sulfate (SLS): HGB
27 Whole Blood Reportable Parameters
WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT (Impedance and Fluorescent Optical), NEUT%, LYMPH%, MONO%, EO%, BASO%, IG%, NEUT#, LYMPH#, MONO#, EO#, BASO#, IG#, RDW-SD, RDW-CV, MPV, RET%, RET#, IRF, RET-He
7 Body Fluid Reportable Parameters
WBC-BF, RBC-BF, TC-BF, MN%, MN#, PMN%, PMN#
Fluorescent Flow Cytometry: WBC-Diff, IG, RET, IRF, PLT-O
Hydrodynamic Focusing, Direct Current: RBC, HCT, PLT
Non-cyanide, Sodium Lauryl Sulfate (SLS): HGB
27 Whole Blood Reportable Parameters
WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT (Impedance and Fluorescent Optical), NEUT%, LYMPH%, MONO%, EO%, BASO%, IG%, NEUT#, LYMPH#, MONO#, EO#, BASO#, IG#, RDW-SD, RDW-CV, MPV, RET%, RET#, IRF, RET-He
7 Body Fluid Reportable Parameters
WBC-BF, RBC-BF, TC-BF, MN%, MN#, PMN%, PMN#